西門子6RA80控制器通電報F60104修復方法,直流傳動器維修,直流控制器(修復分析方法)
1、觀察(cha)R015顯示(shi)值,380V輸入(ru)調速器,正常是在(zai)380~400V。
2、更(geng)換(huan)脈沖觸發電(dian)源板(ban)
3、更換CUD1控制板
工業上有(you)的(de)時(shi)候(hou)會(hui)用(yong)到直流調(diao)速器,這(zhe)種設備在使用(yong)的(de)過程當(dang)中因為某(mou)一些原因,經常會(hui)有(you)使用(yong)不當(dang)的(de)情況,直接的(de)影(ying)響就是導致(zhi)直流調(diao)速器損壞,那么對于工業使用(yong)的(de)直流調(diao)速器建議大家還是選(xuan)擇大廠家進行維修。
如若(ruo)不能解(jie)決您(nin)的問題,可(ke)以(yi)送至恒稅(shui)電氣進行維修。
西門子6RA80控制器通電報F60104修復方法,直流傳動器維修,直流控制器(修復分析方法)
變頻器經常參(can)數初始(shi)化停(ting)機(ji),一般(ban)重(zhong)新(xin)設(she)定參(can)數后,20-30min后故(gu)障又(you)重(zhong)現。
故(gu)障(zhang)分析與維(wei)修:首先判斷(duan)該故(gu)障(zhang)應(ying)該與溫(wen)度(du)有關,因為運(yun)行到20-30min時變頻器(qi)溫(wen)度(du)會升高。用熱風(feng)(feng)焊臺(tai)加熱熱敏電(dian)阻,當加熱到風(feng)(feng)扇啟動的溫(wen)度(du)時,觀察(cha)到控制(zhi)(zhi)面板的LED忽(hu)然(ran)(ran)掉電(dian),然(ran)(ran)后(hou)又亮起(qi)來(lai),接下(xia)來(lai)忽(hu)明忽(hu)暗地閃(shan)動,拿(na)走熱風(feng)(feng)焊臺(tai)30s后(hou)控制(zhi)(zhi)板的LED不(bu)再(zai)閃(shan)動,而是正常顯(xian)示。采用隔離法拔掉所有的風(feng)(feng)扇插頭,再(zai)次(ci)加溫(wen)實驗,故(gu)障(zhang)消除。檢查(cha)發現風(feng)(feng)扇線圈(quan)已短路(lu)。當變頻器(qi)溫(wen)度(du)達到設定溫(wen)度(du)以后(hou),控制(zhi)(zhi)板給出(chu)風(feng)(feng)扇運(yun)轉信號,結果短路(lu)的風(feng)(feng)扇造成(cheng)開關電(dian)源過載關閉輸出(chu),控制(zhi)(zhi)板迅(xun)速(su)失電(dian)而參數(shu)存儲錯誤,造成(cheng)參數(shu)復位。更換(huan)風(feng)(feng)扇后(hou),變頻器(qi)上(shang)電(dian)運(yun)行正常。
西門子6RA80控制器通電報F60104(修復分(fen)析方法);
西門(men)子6RA80維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),西門(men)子直流調速器維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),開不(bu)了機維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),啟動報故障維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),屏(ping)幕不(bu)顯(xian)示維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),黑(hei)屏(ping)維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),勵(li)(li)磁(ci)(ci)故障維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),報警F60105故障維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),跳閘維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),可控硅短路維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),晶閘管燒維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),主(zhu)板(ban)壞(huai)維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),電(dian)源板(ban)維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),勵(li)(li)磁(ci)(ci)板(ban)維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),風機報警維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),超(chao)速維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),電(dian)機抖動維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),無力維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),電(dian)樞電(dian)壓低(di)維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),勵(li)(li)磁(ci)(ci)電(dian)流大維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),測速機報警維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),西門(men)子6RA80控制器維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),6RA80通(tong)訊故障維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),24V過載維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),6RA80模塊炸維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),上電(dian)繼電(dian)器不(bu)吸合維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),6RY1803-0CA04銷售(shou)(shou),6RA80勵(li)(li)磁(ci)(ci)板(ban)銷售(shou)(shou),C98043-A7116-L1-7銷售(shou)(shou),C98043-A7115-L12銷售(shou)(shou),F60097,主(zhu)板(ban)銷售(shou)(shou),C98043-A7105-L4-9銷售(shou)(shou),C98043-A7100-L3-1銷售(shou)(shou),A5F00133580-004主(zhu)板(ban),A5F00101809-011,西門(men)子6RA80報警F60031維(wei)(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)(xiu),西門(men)子6RA80報F60030維修(xiu),F60038,F60042,F60052,F60167,F60105,A31418,F60031,F60010,
C98043-A7105-L4
西門子6RA80控制器通電報F60104修復流程(cheng);
1.客戶根據故(gu)(gu)障來電尋求技(ji)術部幫(bang)助(zhu),工程師認(ren)為,故(gu)(gu)障可由客戶自行解決的,我們(men)將提(ti)供(gong)免費解決方(fang)案
2.不能自行解決(jue)的,客戶可送設備,或快遞設備到公司,公司當天安(an)排維修工(gong)程(cheng)師檢測
3.檢測報告出來后,公司接(jie)單人員及時將(jiang)檢測報告告知客戶
4.征(zheng)詢客(ke)(ke)戶意見(jian),等待客(ke)(ke)戶確認...