西門子828D系統報207995電機編碼器壞;公司從事伺服電機(馬達)的維修工作很多年。
專業維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)各類(lei)型高(gao)精(jing)密伺(si)服(fu)(fu)(fu)電(dian)(dian)(dian)機(ji):伺(si)服(fu)(fu)(fu)電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),主(zhu)軸伺(si)服(fu)(fu)(fu)電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),同步(bu)伺(si)服(fu)(fu)(fu)電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),異步(bu)伺(si)服(fu)(fu)(fu)電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),編(bian)碼器(qi)修(xiu)(xiu)(xiu)理,編(bian)碼器(qi)碼片磨損報廢技術(shu)改(gai)造,步(bu)進伺(si)服(fu)(fu)(fu)電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),主(zhu)軸伺(si)服(fu)(fu)(fu)電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),電(dian)(dian)(dian)主(zhu)軸維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),直(zhi)線電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),多極旋轉(zhuan)電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu),高(gao)速.低速電(dian)(dian)(dian)機(ji)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)
西門子828D系統報207995電機編碼器壞;故障診斷:在數控系統操作面板上查看報警文本,并非由其它原因引起。分析報警代碼,可以判定范圍是伺服驅動系統故障引起的報警,根據編碼器工作原理可知,永磁同步電機啟動前須檢測出轉子的磁極位置,才能確定伺服的通電方式、控制模式及輸出電流的頻率和相位,而檢測磁極位置的功能模塊為電機編碼器,因此可以判斷是編碼器出現了故障,拆開后發現,編碼器進油,經過維修后,西門子加工中心恢復正常。
德國電機故障現象
電機不能啟動,三相電流不平衡,有異常噪聲或振動大,溫升超過允許值或冒煙。
2.產生原因
(1)在檢修和維護保養時碰斷或制造質量問題。
(2)繞組各元件、極(相)組和繞組與引接線等接線頭焊接不良,長期運行過熱脫焊。
(3)受機械力和電磁場力使繞組損傷或拉斷。
(4)匝間或相間短路及接地造成繞組嚴重燒焦或熔斷等。
3.檢查方法
(1)觀察法。斷點大多數發生在繞組端部,看有無碰折、接頭出有無脫焊。
(2)萬用表法。利用電阻檔,對“Y”型接法的將一根表棒接在“Y”形的中心點上,另一根依次接在三相繞組的首端,無窮大的一相為斷點;“△”型接法的短開連接后,分別測每組繞組,無窮大的則為斷路點。
(3)試燈法。方法同前,等不亮的一相為斷路。
(4)兆歐表法。阻值趨向無窮大(即不為零值)的一相為斷路點。
(5)電流表法。電機在運行時,用電流表測三相電流,若三相電流不平衡、又無短路現象,則電流較小的一相繞組有部分短斷路故障。
(6)電橋法。當電機某一相電阻比其他兩相電阻大時,說明該相繞組有部分斷路故障;
(7)電流平衡法。對于“Y”型接法的,可將三相繞組并聯后,通入低電壓大電流的交流電,如果三相繞組中的電流相差大于10%時,電流小的一端為斷路;對于“△”型接法的,先將定子繞組的一個接點拆開,再逐相通入低壓大電流,其中電流小的一相為斷路。
(8)斷籠偵察器(qi)檢查法。檢查時(shi),如果轉子(zi)斷籠,則(ze)毫伏表的讀數應減小。