西門子6SE70伺服驅動報警F008不能復位;技術(shu)服(fu)(fu)務(wu)部有(you)充足的備件(jian)和(he)技術(shu)優良(liang)(liang)的維(wei)(wei)(wei)修(xiu)(xiu)工程師(shi)可為客(ke)戶提(ti)供室內維(wei)(wei)(wei)修(xiu)(xiu)、現場(chang)(chang)維(wei)(wei)(wei)修(xiu)(xiu)、技術(shu)支持服(fu)(fu)務(wu)。所有(you)維(wei)(wei)(wei)修(xiu)(xiu)工程師(shi)均接(jie)受SIEMENS公司專業(ye)技術(shu)培訓,維(wei)(wei)(wei)修(xiu)(xiu)備件(jian)庫(ku)有(you)各(ge)種型(xing)(xing)號(hao)IGBT模塊,各(ge)型(xing)(xing)號(hao)主控制板(ban)(ban)、電源板(ban)(ban)、脈(mo)沖觸(chu)發板(ban)(ban)、信(xin)號(hao)轉換(huan)板(ban)(ban)、散熱風機等維(wei)(wei)(wei)修(xiu)(xiu)備件(jian)。對于MM440、MM430系(xi)列標準傳(chuan)動(dong)(dong)產品、6SE70系(xi)列工程型(xing)(xing)傳(chuan)動(dong)(dong)產品45KW及以(yi)上功率型(xing)(xing)號(hao)變頻(pin)器(qi);直流調速(su)器(qi)均可提(ti)供現場(chang)(chang)服(fu)(fu)務(wu)。除現場(chang)(chang)板(ban)(ban)級更換(huan)維(wei)(wei)(wei)修(xiu)(xiu)外,室內維(wei)(wei)(wei)修(xiu)(xiu)我(wo)們采取(qu)器(qi)件(jian)級維(wei)(wei)(wei)修(xiu)(xiu),將故障(zhang)元件(jian)及不良(liang)(liang)元件(jian)全部進行更換(huan),以(yi)此降低客(ke)戶維(wei)(wei)(wei)修(xiu)(xiu)成本(ben),并從(cong)技術(shu)上保證維(wei)(wei)(wei)修(xiu)(xiu)設備綜合性能。除了以(yi)較好價(jia)格為客(ke)戶提(ti)供產品和(he)服(fu)(fu)務(wu),我(wo)們更關注售后
西門子6SE70伺服驅動報警F008不能復位故(gu)障(zhang)分(fen)析及修復(fu)(fu)方法;故(gu)障(zhang)現象:上電(dian)(dian)自檢(jian)(jian)完(wan)后(hou)(hou),驅(qu)動(dong)報操作控(kong)(kong)制面(mian)(mian)板(ban)(ban)PMU顯(xian)(xian)示(shi)(shi)屏顯(xian)(xian)示(shi)(shi)“FOO8”,復(fu)(fu)位(wei)后(hou)(hou)顯(xian)(xian)示(shi)(shi)“OO9”,啟動(dong)后(hou)(hou)給(gei)定(ding)頻率,20s后(hou)(hou)跳閘,顯(xian)(xian)示(shi)(shi)“FOO8”. 檢(jian)(jian)查處理(參(can)見圖(tu)7):檢(jian)(jian)查電(dian)(dian)流(liu)電(dian)(dian)壓的檢(jian)(jian)測(ce)(ce)部分(fen)運(yun)算放大器N1(TL084)集成塊第(di)(di)7腳的輸出外接電(dian)(dian)阻(zu)(zu)R209,電(dian)(dian)阻(zu)(zu)值(zhi)由正(zheng)常(chang)(chang)時的47Ω變(bian)為(wei)888kΩ,第(di)(di)14腳輸出外接電(dian)(dian)阻(zu)(zu)R203,電(dian)(dian)阻(zu)(zu)值(zhi)由正(zheng)常(chang)(chang)值(zhi)47Ω變(bian)為(wei)185kΩ,更換新(xin)電(dian)(dian)阻(zu)(zu)后(hou)(hou),正(zheng)常(chang)(chang)。 (4)故(gu)障(zhang)現象:操作控(kong)(kong)制面(mian)(mian)板(ban)(ban)PMU顯(xian)(xian)示(shi)(shi)屏顯(xian)(xian)示(shi)(shi)“F008”報警,變(bian)頻器上電(dian)(dian)自檢(jian)(jian),顯(xian)(xian)示(shi)(shi)“009”開機(ji)準備狀態,但是(shi)隨(sui)后(hou)(hou)顯(xian)(xian)示(shi)(shi)“F008”不能啟動(dong)。 檢(jian)(jian)查處理(參(can)見圖(tu)7):檢(jian)(jian)查底板(ban)(ban)電(dian)(dian)壓、電(dian)(dian)流(liu)檢(jian)(jian)測(ce)(ce)部分(fen),發現R56在(zai)線測(ce)(ce)量阻(zu)(zu)值(zhi)為(wei)4.3kΩ,正(zheng)常(chang)(chang)值(zhi)為(wei)900Ω,用熱風槍拆下測(ce)(ce)量阻(zu)(zu)值(zhi)為(wei)1MΩ,已經燒壞。更換新(xin)電(dian)(dian)阻(zu)(zu)值(zhi)后(hou)(hou),運(yun)行正(zheng)常(chang)(chang)。
6SE70伺服驅動報警F008不能復位故障修復流程;首先詢問用戶損壞電氣設備的故障現象及現場情況。
第二步:根據用戶的故障描述,分析造成此類故障的原因。
第三步:對機器進行全面的清潔,確認被損壞的器件,分析維修恢復的可行性。
第四步:根據被損壞器件的位置,找出損壞器件的原因,以免下次類似故障出現。
第五步:出具詳細檢測報告與維修報價,甲方確認報價后進行維修。
第六步:修復后對設備進行負載實驗,正常運行通知甲方,款到發貨
故障(zhang)維修件未修好分(fen)文不收(shou)